Operation and testing
Testing
Test by pushing the test button on the cover. This will sound the alarm if the electronic circuitry,
alarm, and battery are working. If no alarm sounds, the unit has defective batteries or other failures.
DO NOT use an open flame to test your alarm, you could damage !he alarm or ignite
combustible materials and start a structure fire.
NOTE: WEEKLY TESTING IS REQUIRED
Normal Condition
The red LED on the front should flash every 48 seconds to show that the alarm is active.
Alarm Condition
When the Alarm senses products of combustion and sounds the audible alarm, the red LED will flash one
flash/ second. The flashing LED and pulsating alarm will continue until the air is cleared.
Low Power Pack Condition
IMPORTANT: Your smoke alarm requires the power pack to
have sufficient capacity of power to operate correctly.
Should your smoke alarm entera low power pack condition, the unit will emit an audible chirp once every 48
seconds. with light flash once. When this occurs you must replace the alarm immediately. Your smoke alarm
will continue to warm of this low power pack condition for at least 30 days, however, failure to change
the alarm after this time would mean your smoke alarm may have insufficient power to alert you in a real
fire situation.
Fault indication
The alarm chirp occurs every 48 seconds.
Alarm silence
During the unit is alarming, push the test button, it will be paused the unit alarming for approx. 8
minutes. The red LED will flash once every 8 seconds, it indicates the smoke alarm device is running into
the silence mode. If your smoke alarm emits the full alarm signal and you are not testing the unit, the
smoke alarm is warning you of a potentially dangerous situation that requires your immediate attention.
Only use the alarm silence function after making sure that there is no ongoing fire emergency situation.
Do not block the vents on the alarm or disable the smoke alarm in any way, as this will remove your
protection. Smoke alarms can sometimes react to cooking fumes or other non emergency situations. In the
event of a known false alarm your smoke alarm can be temporarily silenced by pressing the test button.
Your alarm will automatically return to full sensitivity within 8 minutes.
Note:
- Press and release the silence button, the alarm sound will stop.
-
Your alarm will silence and enter into a reduced sensitivity reset cycle for approximately 8 minutes.
- During the reduced sensitivity reset cycle, the red LED will flash once every 8 seconds.
-
Your alarm will automatically retum to full sensitivity on completion of the reset cycle and the red LED
will revert to flashing once every 48 seconds.
Danger
Never ignore any alarm ignoring the alarm may result in injury or death.If your smoke alarm activates and
alarms and you are not absolutely certain of the source of the smoke, get everyone out of the house
immediately.